CANON’S DOSE REDUCTION TECHNOLOGIES

AIDR3D

AIDR 3D (Adaptive Iterative Dose Reduction 3D)

AIDR 3D is a sophisticated algorithm that has been designed to work in both the raw data and reconstruction domains. The collective AIDR 3D process results in robust noise reduction, which is essential for achieving ultra low-dose examinations in routine clinical imaging. This iterative algorithm is superior to non-iterative approaches in removing background noise while preserving diagnostic information.


INTEGRATED, ROBUST DOSE MANAGEMENT

Dose reduction is considered in every step of the system design, because Canon engineers recognize that all the small dose savings add up. For example, the gantry is designed with the X-ray tube located further from the patient, reducing the skin entrance dose. Astelion Advance Edition employs the latest dose reduction technologies such as SUREExposure 3D Adaptive and AIDR 3D in the standard configuration.

Canon's Commitment to Dose Reduction

COMPREHENSIVE LOW-DOSE EXAMINATION

Astelion Advance Edition dose reduction and reporting technologies are integrated into every step of each scan performed, ensuring the highest possible level of patient safety.

Besides that this system incorporates 0.5 mm Quantum Detector technology and provides consistent image quality with an industry-leading low-contrast resolution of 2 mm at 0.3%.

EXAM PLAN

PROTOCOL SELECTION

After patient registration Astelion Advance Edition selects the correct adult or child protocols automatically.

NAVI MODE OPERATION

Astelion Advance Edition’s Navi Mode is perfectly suited for fast patient throughput. Regardless of whether you are an expert or a novice, this unique function lets you take advantage of the system’s high performance features quickly and with ease.

DOSE CHECK

The Dose Check software helps ensure that the user-defined radiation dose limits cannot be exceeded by incorrect operation of the system.

Navigation

RECONSTRUCTION

AIDR 3D

AIDR 3D can be applied to all acquisition modes in routine clinical use and is able to remove up to 50% of image noise, resulting in dose reductions of up to 75%.

AIDR 3D Reconstruction


SCAN

SUREEXPOSURE 3D ADAPTIVE

The integration of dose reduction technologies is essential for optimal dose management. AIDR 3D has therefore been seamlessly integrated with SUREExposure 3D, Canon’s automatic tube current modulation software. SUREExposure 3D modulates the exposure for each patient based on a preset target level of image quality. When combined with AIDR 3D, X-ray exposure is automatically reduced before the scan, while maintaining the preprogrammed image quality adjusted based on the expected level of noise reduction. This combination provides a unique solution for robust dose management.

SURE Exposure

REPORT

DOSE REPORT

In accordance with IHE recommendations, the Radiation Exposure Monitoring Profile function is provided in the software. This function automatically records all scanning data, enabling accurate tracking of the dose for a particular study.

Dose Report

MINIMUM SPACE – MAXIMUM EFFICIENCY

MINIMAL SPACE REQUIREMENT
Delivering powerful performance in a small space, Astelion has been designed with a footprint of just 10.4 m2. Thanks in part to its flexible siting requirements, Astelion can be up and running in a remarkably short time.

ENVIRONMENTALLY FRIENDLY
Canon is committed to the development and manufacture of environmentally conscious products. Comprehensive optimization of the energy consumption of all system components reduces overall system power requirements. By employing energy-saving techniques such as automatic control of the gantry fan, power consumption in standby status is reduced by 40% compared to conventional systems.

ECONOMIC EFFICIENCY
AIDR 3D enables low dose, excellent image quality, and great cost performance. How does it increase patient throughput? With AIDR 3D, cooling time is eliminated, so more examinations can be performed.